Aviation
 
 

History of FloScan Aircraft Flow Transducers

In 1972, Aerosonics, (a leading U.S. avionics manufacturer at the time) began testing the Series 200 flow transducers to determine its suitability for use in general aviation aircraft. Prior to that time there had not been a generally acceptable transducer for this application. The company required a fuel flow transducer which would withstand the vibration of an aircraft engine. It also had to meet the important FAA regulation regarding blocked rotor pressure drop which could not be more than 1.5 times the spinning rotor pressure drop.  Our design far surpassed the test requirement since a blocked rotor does not change the pressure drop of a FloScan flow transducer.  For this reason, and because of their superior accuracy and extraordinary repeatability, FloScan transducers quickly become the dominate fuel flow measuring sensors for general aviation with over 250,000 units sold.  In fact, the pilots of the record breaking, non-stop around-the-world flight of the "Voyager" in 1986, depended on FloScan transducers for accurate fuel flow measurement.


Series 200 Flow Sensor Specifications

Description:
Series 200 Turbine Flow Transducers measure flows of hydrocarbon fuels such as gasoline, kerosene, and #2 diesel fuel and other light transmitting, non-corrosive liquids of similar viscosity.  Typical fuel flow applications include aircraft fuel monitoring systems; gasoline, diesel, and gas turbine engine test stands; and industrial furnaces.

The transducers give repeatable signals on gasoline across a 100 to 1 flow range down to 0.3 GPH.  The higher viscosity of diesel fuel reduces signal repeatability at flow rates below 2 GPH.  Pressure drops are very low compared to other turbine flow transducers.  The transducer bearing system is rated for continuous operation at the upper end of the flow range.

The transducers produce a current pulse signal from an opto-electronic pickup with a preamplifier. 

Principal of Operation:
Liquid enters the flow chamber tangentially, follows a helical flow path, and exits vertically, thereby venting any entrained vapor bubbles.  The rotational velocity of the liquid is directly proportional to flow rate.  A neutrally buoyant rotor spins with the liquid between V-jewel bearings.  Rotor movement is sensed when notches in the rotor interrupt an infrared light beam between an LED and phototransistor.

The vapor venting design requires that the transducer be positioned with the electrical connectors pointing up.  Turbulence caused by valves or sharp elbows mounted close to the transducer inlet can affect transducer K-Factor and should be minimized.



Performance Specifications:

Model Number

201A-6

201B-6

201C-6

Flow Range , Gasoline 

0.3 – 30 GPH

0.6 – 60 GPH

2.0 – 80 GPH

#2 Diesel

2.0 – 30 GPH

3.0 – 60 GPH

8.0 – 80 GPH

Approximate K Factor (Pulses/Gallon @ 16 GPH),

32,000

28,000 – 31,000 

24,000

#2 Diesel

33,000

28,000

25,000

Pressure Drop,  Gasoline

0.6 psi @ 15 GPH

1.2 psi @ 30 GPH

1.4 psi @ 40 GPH

2.4 psi @ 30 GPH

4.8 psi @ 60 GPH

5.8 psi @ 80 GPH

#2 Diesel

0.8 psi @ 15 GPH

1.5 psi @ 30 GPH

1.8 psi @ 40 GPH

3.0 psi @ 30 GPH

6.0 psi @ 60 GPH

7.2 psi @ 80 GPH

Repeatability Between Measurements

½% @ 16 GPH

½% @ 16 GPH

½% @ 16 GPH

Working Pressure

200 psi

200 psi

200 psi

Temperature Range

-65° / 100°C

-65° / 100°C

-65° / 100°C

Bearing Life Expectancy

10,000 hr. min.

10,000 hr. min.

10,000 hr. min.

NOTE:  All flow transducers are tested and marked with K-factor at 16 GPH.  Repeatability at 16 GPH is guaranteed to ½%.  Transducers are available with calibrated K-factors at additional cost.


 
Material Specifications:

Flow Transducer Body Die-cast Aluminum, Cadmium Plated, Dichromate Finish
Rotor Nylon 6/12
Rotor Pivot Stainless Steel, Carpenter 420
Phototransistor SD 1440
Light Emitting Diode SE 1450
Connectors 22 Gauge Wire Leads (3)

Electrical Specifications:
12 to 15 VDC between RED (+) wire and BLACK (-) wire.  30 to 50 mA at 12 VDC.

Signal Specifications:
Open collector transistor output on WHITE wire.  Sensor will pull-down to 1.0 volt with 10-15k ohm pull-up resistor installed.


Dimensions (inches)                         *click on diagram to enlarge picture*

NOTE: FloScan reserves the right to change flow sensor specifications without notice.


Clients

Piper www.newpiper.com
Cessna www.cessna.com
Shadin www.shadin.com
JPI www.jpinstruments.com
Mooney www.mooney.com
Symphony Aircraft www.symphonyaircraft.com
Instrument Tech www.instrumenttech.com 
Machen www.aerostaraircraft.com
Blue Mountain Avionics www.bluemountainavionics.com
Rocky Mountain Avionics www.rkymtn.com
Flight Data Systems www.fdatasystems.com
Avionik GmbH www.avionic.de
TL Elektronic www.tlelektronic.cz
Insight Avionics www.insightavionics.com
BAE Systems www.baesystems.com


FREE QUOTE REQUEST
Click here to request a free price quotation.

INSTALLATION VIDEO
Click here to view our new installation video which outlines a Series K system installation showing both plumbing and wiring procedures for the standard flow and high flow sensor models. The new Series K fuel flow sensor design also enhances system performance and accuracy. Best of all, the simplified procedures allow for do-it-yourself installation